Ion Chambers for Sale

Pressurized and non-pressurized Ion Chamber Survey Meters

For Detection of X-Ray, Gamma, Alpha, Beta Radiation.

TBM-IC Mark 5 Ion Chamber by Technical Associates
 TBM-IC-Mark 5 Ion chamber - non-pressurized The flat response TBM-IC-MV is a fast, sensitive ion chamber survey meter which measures gamma and x-ray radiation, and detects some alphas, betas. The survey meter features a 2.5 inch diameter x 3.5 inch length air ion chamber coupled to a stable solid state Mosfet input electrometer. Rate range is 0.1 mR/h to 9.999 R/h in a single range. Dose range is 0.01mR - 99.9R in a single range.
TBM-IC-XRAY Ion Chamber by Technical Associates
TBM-IC-X-Ray Ion Chamber This compliance test ion chamber provides accurate compliance testing of a wide variety of X-Ray machines, televisons and computer monitors, luggage and personell x-ray scanners. Rate Range is 0.01 mR/h to 100.00 mR/h in one range. Dose range is 0.01 mR to 10 R.
TBM-IC-Pulse-x by Technical Associates
TBM-IC-Pulse-X New - for Nano Second pulsed X-ray radiation The TBM-IC-Pulse-X useful in non-destructive testing or other industrial or medical applications where pulsed x-rays in the nano-second range, are used.
Ion Chamber, TBM-IC-AJI by Technical Associates
Model TBM-IC-AJI Wide Range Ion Chamber Detects Alpha, Beta, Gamma / X-ray. This Ion Chamber can detect X-ray pulse as low as 0.2 Micro R. The unit is non-pressurized and requires no HAZMAT shipping.
TBM-IC-LR Wide Range Ion Chamber by Technical Associates
Model TBM-IC-LR Wide Range Ion Chamber The TBM-IC-LR Ion Chamber is a fast response, sensitive portable radiation detector for all gammas including low energy. Range includes 0.01 mR/hr to 1 R/hr. This chamber detects axially below 5 keV.
TBM-IC-RN Radon Detector by Technical Associates
TBM-IC-RN Radon Monitor This hand-held radon meter detects 10 picoCi/l of radon in 5 seconds and detects public release level of radon in less than 10 minutes. The unit consists of an air ion chamber (2.9" D x 3.5" L) coupled to a stable solid state MOSFET input electrometer with built-in A to D converter to read out directly in nCi/liter. Range is 10 picoCi/l to 1 µCi/l.
Model FIL-7DP Ion Chamber Area Monitor Model FIL-7DP Wide Range Ion Chamber Area Monitor This unit is ideal for nuclear reactors, hot cells, irradiators and other facilities handling radioactive materials or X-rays.The detector is an air equivalent ion chamber. Standard systems use Model IC-2 (for gamma) or Model IC-1 (for beta-gamma). Both models have graphite lined phenolic walls and an active free air volume of 2 liters. Standard range is 0.1 - 10,000 mR/h.
Fluke 451P Model 451P Ion Chamber- Pressurized This ion chamber was designed to measure leakage and scatter around diagnostic X-ray and radiation therapy suites. It can measure Gamma and X-ray at the micro Roentgen level, for energies above 25 keV.
Fluke 451B
Model 451B  Ion Chamber with Beta Slide - non-pressurized This ion chamber measures beta, gamma and X-ray radiation. It detects Beta above 100 keV, and Gamma above 7 keV. The unit includes a sliding shield for alpha and beta discrimination.

 

Waterproof Pelican Cases Available 

Nuclear Instrumentation

Dosimetry Shielding Sources Specials

Hepa Vacuums

Chemical Detection

Marinelli Beakers

Fume Hoods

Accessories

Emergency Response

Nuclear Medicine

Radiation Therapy Search Home

Direct Scientific  /  tel (310) 589 0601 /   Email

contact us: en espaņol, auf Deutsch
Open 8:00 AM - 5:00 PM Pacific Standard Time
Follow us on twitter and youtube.
visit our youtube channel
follow us on twitter
Check out our instrument demos.