The DSM-506 Emergency Kit features the digital DSM-506 Survey/Scaler meter which detects most alpha, beta, and gamma contamination fields. Sensitivity ranges from background to 2000 mR/hr. The DSM-506 utilizes an internal energy compensated G-M detector for high range. External probes include the pancake G-M probe (model HP-265) and a high sensitivity tissue equivalent scintillation probe (MRSP-1). The meter measures in dose or cpm, which can be switched from the front panel. The timed count scaler function provides more accuracy in low level contamination measurements. Digital display, auto-ranging and diagnostics are a user-friendly improvement over the older analog systems. Other components of the system include a 1 micro curie cesium check source. All components of the system are contained in a durable hard case for easy storage and portability.

Components:

DSM-506 Survey Meter Specifications

Input Sensitivity: 0.050v
Dose/CPM Switchable: External Dose/CPM switch
Display units: (four Digit LCD with/backlight) CPM, KCPM, CPS, μR/hr, mR/hr, R/hr, μSv/hr, mSv/hr, Sv/hr
Display refresh rate: 0.8-3.0 seconds, adjustable
Display Back Light: Toggle Switch on for 30 seconds auto OFF, Repeat as needed
Scaler Timed Count: Settings 0.10-2550 seconds in 10 second increments
Probe 1 Range: (HP-265 Pancake probe) 0-200 mR/hr, 0-999,9 K CPM (other ranges and probes available)
Internal Detector: EC GM Detector 0-2,000 mR/hr - 0-999.9Kcpm
Scaler Range: 0-999.9Kcpm
Diagnostics: Low Battery, Over Range, HV out of range
Alarm: Adjustable from 5% to 95% of full scale for Dose and CPM
Over Range Alarm: Adjustable 10% above maximum range (dose calibration only)
Electrically Linearity: < 5%
Response Time: Fast: 10-250 seconds , Slow: adjustable from 10 --250 seconds
Drift: < 5%
Environmental: -20ıF (-28ıC) to140ıF (60ıC) | 5-95% RH IPX4 Housing
#1 High Voltage Adjustable: 300-1500 VDC | Regulation ±1%
#2 High Voltage Adjustable: 300-1500 VDC | Regulation ±1%
Audio: (loud click per input event) On/Off switch on Front panel
Battery: six AA Alkaline (Nominal 200 hrs Operation)
Display: four digit 0.75” (19mm) tall with Led backlight
Circuitry: Digital Microprocessor Controlled
Dimensions: 5.5" (14cm) H X 4" (10 cm) W X 7" (18cm) L
Weight: 2.5lbs (1.2 kilo) W/ Batteries
Construction: Heavy Duty Cast Aluminum & Stainless Steel

HP-265 G-M Pancake Probe Specifications

HP-265 pancake probe by Johnson NuclearDescription: Long life halogen pancake G-M detector with 1.6 mg/cm2 End Window
Efficiency (4pi geometry): Typically 5%-C-14; 22%-Sr-90/Y-90; 19%-Tc-99; 32%-P-32; 15%-Pu-239, Gamma dose to 200 mR/hr (Based on 137Cs calibration)
Operating Voltage: 900 vdc
Window Thickness: 1.6mg/cm2
CPM/mR/hr: (137CS): 2,500
Energy Response: 3.5 MeV alpha, 20 MeV gamma, 100 keV beta
Sensitive Area: 15 cm2
Finish: Polyurethane Coated Aluminum
Dimensions: 2.75" diameter X 11" long
Weight: 16 ounces
Environmental: 20º - 60ºC, 5% - 95% RH non-condensing---IPX4
Construction: Polyurethane coated aluminum probe housing, nylon coated stainless steel probe clip

MRSP-1 Detector Specifications

MRSP-1 probe by WB JohnsonGeneral:  Micro R Detector
Range: 0 - 10,000 Micro R
Energy Response: Gamma: 20 keV-2MeV
Operating Voltage: 900 vdc
Window Density: 7 mg/cm2
Dead Time: <5 μSec
Sensitivity to Cs-137: 60 CPM/μR/hr
Sensitive Area: 1” (2.54cm) X 1” (2.54cm)
Environmental: -20°F (-28° C)— 140°F (60° C) — 5 - 95% RH, IPX4 Housing
Dimensions: 1.875” (4.76cm) Diameter X 6” (15.2cm) Long
Weight: 0.5 Pounds (.23 kilos)

Check Source and Holder

Cs-137 Check Source

Cs-137 1 uCi, 1 inch check source with holder

Waterproof Hard Case - Plano, Pelican or similar

pelican case, 1500